ANALISIS EFEKTIVITAS MENARA PENDINGIN PADA PLTP KAMOJANG UNIT V PT. PERTAMINA GEOTHERMAL ENERGY AREA KAMOJANG SEBELUM DAN SESUDAH PERAWATAN

PRATAMA, REPLYINDRA and PRAMONO, WIDYA ANDIKA (2025) ANALISIS EFEKTIVITAS MENARA PENDINGIN PADA PLTP KAMOJANG UNIT V PT. PERTAMINA GEOTHERMAL ENERGY AREA KAMOJANG SEBELUM DAN SESUDAH PERAWATAN. Diploma thesis, ITPLN.

[thumbnail of SOFTFILE_TUGAS AKHIR_REPLYINDRA PRATAMA.pdf] Text
SOFTFILE_TUGAS AKHIR_REPLYINDRA PRATAMA.pdf
Restricted to Repository staff only

Download (5MB)

Abstract

Pembangkit ramah lingkungan yang disebut pembangkit listrik tenaga panas bumi menghasilkan listrik dengan memutar turbin secara langsung memanfaatkan uap panas bumi. Cooling tower berfungsi untuk menurunkan suhu air kondensat dari hasil kondensor yang dipompa melalui hot well pump. Karena fungsinya sangat penting, maka kinerja cooling tower harus dijaga. Salah satu cara untuk mengetahui pengaruh efektivitas sebelum dan sesudah perawatan adalah dengan melakukan analisis untuk mengetahui parameter efektivitas cooling tower. Analisis ini dilakukan dengan menggunakan metode Range dan Approach. Hasil penelitian menunjukkan bahwa Range secara aktual selama setahun adalah sebesar 20,78°C, selisih 4,08°C dari nilai Range secara teori. Sedangkan, untuk nilai Approach aktual selama setahun adalah sebesar 7,42°C, selisih 1,42°C dari nilai Approach secara teori. Nilai efektivitas selama setahun berada di angka 73,66% Setalah dilakukannya perawatan pada filler pack, spray nozzle dan bassin terjadi peningkatan nilai efektivitas cooling tower, sebelum perawatan adalah 73,21% dan setelah perawatan menjadi 76,48%. Ini menunjukan, perawatan menjadi faktor penting dalam optimalisasi kinerja menara pendingin.

An environmentally friendly power plant called a geothermal power plant produces electricity by rotating a turbine directly utilizing geothermal steam. The cooling tower functions to lower the temperature of the condensate water from the condenser pumped through a hot well pump. Because its function is very important, the performance of the cooling tower must be maintained. One way to determine the effect of effectiveness before and after treatment is to conduct an analysis to determine the parameters of the cooling tower effectiveness. This analysis is carried out using the Range and Approach methods. The results of the study showed that the actual Range for a year was 20.78 ° C, a difference of 4.08 ° C from the theoretical Range value. Meanwhile, the actual Approach value for a year was 7.42 ° C, a difference of 1.42 ° C from the theoretical Approach value. The effectiveness value for a year was at 73.66%. After maintenance was carried out on the filler pack, spray nozzle and bassin, there was an increase in the cooling tower effectiveness value, before treatment it was 73.21% and after treatment it became 76.48%. This shows that maintenance is an important factor in optimizing the performance of the cooling tower.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Efektivitas cooling tower, filler pack, spray nozel, bassin, metode Range dan Approach Effectiveness of cooling tower, filler pack, spray nozzle, basin, Range and Approach methods
Subjects: Skripsi
Bidang Keilmuan > Teknik Mesin
Divisions: Fakultas Teknologi dan Bisnis Energi > S1 Teknik Mesin
Depositing User: Nurul Hidayati
Date Deposited: 11 Sep 2025 02:04
Last Modified: 11 Sep 2025 02:04
URI: https://repository.itpln.ac.id/id/eprint/866