STUDI PERHITUNGAN EFISIENSI MOTOR INDUKSI PENGGERAK KIPAS PENDINGIN SISTEM PELUMAS UPJP PRIOK GT 2.2 DAN GT 2.3

Budiawan, Lidya Utami and Sudibyo, Uno Bintang (2017) STUDI PERHITUNGAN EFISIENSI MOTOR INDUKSI PENGGERAK KIPAS PENDINGIN SISTEM PELUMAS UPJP PRIOK GT 2.2 DAN GT 2.3. Diploma thesis, ITPLN.

[thumbnail of 1. Cover.pdf] Text
1. Cover.pdf

Download (55kB)
[thumbnail of 2. Pengesahan Daftar Isi.pdf] Text
2. Pengesahan Daftar Isi.pdf

Download (162kB)
[thumbnail of 3. BAB 12345 Lube Oil Delta.pdf] Text
3. BAB 12345 Lube Oil Delta.pdf
Restricted to Registered users only

Download (725kB)
[thumbnail of 4.Daftar Riwayat Hidup.pdf] Text
4.Daftar Riwayat Hidup.pdf

Download (31kB)

Abstract

Motor induksi tiga fasa merupakan mesin listrik yang mengubah energi listrik menjadi energi gerak. Salah satu penggunaan motor induksi yaitu sebagai penggerak kipas pendingin sistem pelumas UPJP Priok GT 2.2 dan GT 2.3. Kipas tersebut penting untuk mendinginkan pelumas sebelum digunakan untuk melumasi bantalan dan poros pada turbin gas, kompresor dan generator. Pemakaian motor selama bertahun-tahun akan mempengaruhi kinerja motor tersebut. Karena itu, dibutuhkan studi perhitungan efisiensi motor induksi yang dilakukan dengan pengetesan tanpa beban dan pengetesan rotor terkunci. Sesuai standar batas minimal efisiensi 85%, dapat disimpulkan bahwa kondisi motor induksi penggerak kipas pendingin sistem pelumas UPJP Priok GT 2.2 dan GT 2.3 cukup baik karena masih dalam batas yang dipersyaratkan.

A three phase induction motor is an electric machine that converts electrical energy into mechanical energy. One of the utilization of an induction motor is for lubricating system cooling fan at UPJP Priok GT 2.2 and GT 2.3. The fan is important to cool the lubricant before used to lubricate the bearings and shaft on the turbine gas, compressors, and generators. The motor has been using for many years and will affect it’s performance. Therefore, required efficiency calculation study are done by no load test and locked rotor test. According to the standard minimum limit of the efficiency of 85%, it can be concluded that the condition of a cooling fan induction motor for lubricating system at UPJP Priok GT 2.2 and GT 2.3 are good enough because it is still within the limit.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: motor induksi, kipas, efisiensi induction motors, fan, efficiency
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 26 Nov 2025 12:22
Last Modified: 26 Nov 2025 12:22
URI: https://repository.itpln.ac.id/id/eprint/4112

Actions (login required)

View Item
View Item