STUDI PROTEKSI MOTOR LISTRIK PENGGERAK FORCED DRAFT FAN DI PLTU MUARA KARANG UNIT 4

Rifahardiansyah, Bima and Isworo, lakso (2017) STUDI PROTEKSI MOTOR LISTRIK PENGGERAK FORCED DRAFT FAN DI PLTU MUARA KARANG UNIT 4. Diploma thesis, ITPLN.

[thumbnail of Gabungan Sampul awal.pdf] Text
Gabungan Sampul awal.pdf

Download (218kB)
[thumbnail of BAB I FD fan.pdf] Text
BAB I FD fan.pdf

Download (125kB)
[thumbnail of BAB II FD fan.pdf] Text
BAB II FD fan.pdf

Download (393kB)
[thumbnail of BAB III FD FAN.pdf] Text
BAB III FD FAN.pdf
Restricted to Registered users only

Download (285kB)
[thumbnail of BAB IV FD FAN.pdf] Text
BAB IV FD FAN.pdf
Restricted to Registered users only

Download (671kB)
[thumbnail of BAB V FD FAN.pdf] Text
BAB V FD FAN.pdf
Restricted to Registered users only

Download (114kB)

Abstract

Motor asinkron (motor induksi) banyak di gunakan pada pembangkit sistem tenaga listrik seperti contoh nya pada Forced Draft Fan (FDF) .Dalam sistem tenaga listrik, supaya dapat beroperasi dengan andal. Maka diperlukan sistem proteksi. Sistem proteksi berperan penting dalam mendeteksi adanya gangguan dan untuk mencegah kerusakan yang diakibatkan gangguan. sistem proteksi yang baik akan mengisolasi daerah gangguan dan mencegah terjadinya padam pada sistem lain yang tak terganggu. Hal ini akan meningkatkan keandalan sistem yaitu menjaga kontinyuitas suplai beban. Skripsi ini bertujuan untuk menyampaikan studi proteksi motor listrik besar dengan studi kasus Forced draft fan (FDF) di Unit Pembangkit PLTU Muara Karang .Dari hasil studi yang didapat pada skripsi didapatlah perhitungan TMS OCR sebesar 2,5 , setting itu sudah dapat dikatakan baik , berdasarkan kurva yang dilakukan di simulasi ETAP 12.6.0

Asynchronous motor is widely used in powerplant, for example in Forced Draft Fan. In electrical power system, protection system is required to operate reliably. Protection system ha a very important role to detect fault and to prevent the damage that caused by it. A good protection system will isolate the fault and prevent the other system which is not failing becomes failed. This will improve the reliability of the system and maintaining continuity of load supply. This will improve the reliability of the system and maintaining contuinity of load supply. This thesis aims to convey the protection study of large electric motor with case study of Forced Draft Fab (FDF) in Muara Karang Power Plant. From the result of study that value calculation TMS OCR = 2,5, it can already be said good based on chart that simulation on applicatiom ETAP 12.6.0.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Proteksi, FDF, PLTU, Motor Asinkron,Rele Protection, FDF,Power Plant, Asynchronous Motor, Relay
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 01 Dec 2025 06:51
Last Modified: 01 Dec 2025 06:51
URI: https://repository.itpln.ac.id/id/eprint/4263

Actions (login required)

View Item
View Item