PROTEKSI GANGGUAN TANAH TERBATAS ( RESTRICTED EARTH FAULT ) PADA TRAFO 70 MVA 150/13,8 kV PLTA PB. SOEDIRMAN

Rakhman, Faisal and Sukmajati, Sigit (2017) PROTEKSI GANGGUAN TANAH TERBATAS ( RESTRICTED EARTH FAULT ) PADA TRAFO 70 MVA 150/13,8 kV PLTA PB. SOEDIRMAN. Diploma thesis, ITPLN.

[thumbnail of COVER, LEMBAR PENGESAHAN, DAFTAR ISI.pdf] Text
COVER, LEMBAR PENGESAHAN, DAFTAR ISI.pdf

Download (333kB)
[thumbnail of BAB I DAN BAB II FAISAL RAKHMAN.pdf] Text
BAB I DAN BAB II FAISAL RAKHMAN.pdf

Download (1MB)
[thumbnail of BAB III FAISAL RAKHMAN.pdf] Text
BAB III FAISAL RAKHMAN.pdf
Restricted to Registered users only

Download (241kB)
[thumbnail of BAB IV FAISAL RAKHMAN.pdf] Text
BAB IV FAISAL RAKHMAN.pdf
Restricted to Registered users only

Download (264kB)
[thumbnail of BAB V FAISAL RAKHMAN.pdf] Text
BAB V FAISAL RAKHMAN.pdf
Restricted to Registered users only

Download (7kB)
[thumbnail of DAFTAR PUSTAKA.pdf] Text
DAFTAR PUSTAKA.pdf

Download (6kB)
[thumbnail of CV FAISAL RAKHMAN.pdf] Text
CV FAISAL RAKHMAN.pdf

Download (100kB)
[thumbnail of LEMBAR BIMBINGAN .pdf] Text
LEMBAR BIMBINGAN .pdf

Download (177kB)

Abstract

Energi listrik merupakan kebutuhan masyarakat yang penting pada saat ini, untuk itu diperlukan kesinambungan dalam penyaluran energi listrik. Peranan transformator tenaga dalam sistem penyaluran energi listrik adalah sebagai peralatan listrik yang mengubah tegangan listrik dari tegangan tinggi ke tegangan menengah maupun sebaliknya. Pengoperasian transformator tenaga dapat terganggu, apabila terjadi gangguan diluar ataupun didalam transformator itu sendiri. Untuk itu diperlukan pengaman transformator terhadap gangguan yang mungkin terjadi. Salah satu peralatan pengaman transformator tenaga adalah relai gangguan tanah terbatas (Restricted Earth Fault Relay) yang digunakan sebagai pengaman terhadap gangguan hubung singkat fasa ke tanah. Setelah membandingkan setting arus relai hasil perhitungan yaitu untuk gangguan hubung singkat fasa ketanah sisi 13,8 kV didapat setting arus sebesar 0,17 A sedangkan relai yang sudah terpasang sebesar 0,4 A. Sedangkan untuk gangguan yang terjadi disisi 150 kV, dalam perhitungan arus setting didapat sebesar 0,15 A sedangkan arus setting yang terpasang sebesar 0,15 A. Maka dilihat dari data tersebut, dapat disimpulkan bahwa relai masih mampu menahan arus gangguan hubung singkat tersebut dan tidak perlu dilakukan perubahan atau penyetelan ulang.

Electrical energy is an important human need at this time. Therefore, it requires continuity in the distribution of electrical energy. The role of power transformer in electrical energy distribution system is as electrical equipment that convert voltage from high voltage to low voltage and reverse. The operation of the power transformer may be disrupted if there is kind of outside interference or within the transformer itself. So, this requires a safety transformer againts the interference that might happen. One of the power transformer safety equipments is called Restricted Earth Fault Relay which is used as a safety equipments againts shortcircuit phase to ground. After comparing the data of Restricted Earth Fault Relay settings installed on the transformer and the data from the result of short-circuit phase to ground. After comparing current relay setting, result of the calculation is for short circuit of the ground phase 13,8 kV, current setting of 0,17 A while the relay already installed of 0,4 A. Whereas the disruption the occurred at 150 kV, in calculation current relay setting is 0,15 A while the current setting is attached by 0,15 A. The conclusion is that the relay still able to withstand the short current circuit and no change or reset.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: proteksi, trafo, restricted earth fault relay protection, transformer, restricted earth fault relay
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 02 Dec 2025 05:31
Last Modified: 02 Dec 2025 05:31
URI: https://repository.itpln.ac.id/id/eprint/4305

Actions (login required)

View Item
View Item