Current Transformer (CT) yang biasa disebut transformator arus merupakan peralatan yang mengubah besaran arus dari besar ke kecil ataupun sebaliknya sesuai dengan kebutuhan yang diperlukan agar dapat dimanfaatkan sebagai input pada alat metering dan perantara pengukuran arus, di mana terdapat keterbatasan kemampuan baca alat ukur. Misalkan pada sistem saluran tegangan tinggi, arus yang mengalir adalah 2000A, sedangkan alat ukur yang ada hanya sebatas 5 A. Maka dibutuhkan sebuah CT yang mengubah representasi nilai aktual 2000A di lapangan menjadi 5A sehingga terbaca oleh alat ukur. Fungsi CT adalah untuk memperoleh arus yang sebanding dengan arus yang hendak dipergunakan, dan untuk memisahkan sirkuit dari sistem yang arus nya hendak diukur (yang selanjutnya di sebut sirkuit primer) terhadap sirkuit dimana instrumen tersambung (yang selanjutnya disebut sirkuit sekunder dengan arus sebesar 1 A atau 5 A yang dipergunakan untuk pengukuran atau proteksi. Karena adanya perbedaan antara arus yang masuk di sisi primer dengan yang terbaca disisi sekunder, dapat menimbulkan perbedaan ratio transformasi arus yang sebenarnya dengan kenyataannya. Bila CT dipergunakan untuk pengukuran energi (kWh), kesalahan arus ini sangat berpengaruh terhadap pengukuran energi.
Current Transformer (CT) commonly called current transformer is a device that changes the amount of current from large to small or vice versa according to the needs needed so that it can be used as input on metering devices and intermediaries for measuring flows, where there is limited reading ability. For example, in a high voltage channel system, the current flowing is 2000A, while the measuring device is only limited to 5 A. Then a CT is needed that changes the actual representation of 2000A values in the field to 5A so that it is read by a measuring instrument. The CT function is to obtain a current that is proportional to the current to be used, and to separate the circuit from the system whose current is to be measured (which is then called the primary circuit) to the circuit where the instrument is connected (hereinafter called a secondary circuit with a current of 1 A or 5 A that is used for measurement or protection Because of the difference between the incoming current on the primary side and the one read on the secondary side, it can cause a difference in the actual current transformation ratio, if CT is used for energy measurement (kWh), this current error is very affect energy measurement.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Current Transformer, akurasi, kWh meter Current Transformer, accuracy, KWh meter. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 12 Feb 2026 07:18 |
| Last Modified: | 12 Feb 2026 07:18 |
| URI: | https://repository.itpln.ac.id/id/eprint/5005 |