PENYETELAN RELE DIFFERENSIAL PADA TRANSFORMATOR 30 MVA 150/20 kV DI GARDU INDUK JATAKE

SYAM, NURUL ANNISA and Erlina, Erlina (2018) PENYETELAN RELE DIFFERENSIAL PADA TRANSFORMATOR 30 MVA 150/20 kV DI GARDU INDUK JATAKE. Diploma thesis, ITPLN.

[thumbnail of Cover.pdf] Text
Cover.pdf

Download (73kB)
[thumbnail of i-vi.pdf] Text
i-vi.pdf

Download (1MB)
[thumbnail of BAB I.pdf] Text
BAB I.pdf

Download (96kB)
[thumbnail of BAB II.pdf] Text
BAB II.pdf

Download (602kB)
[thumbnail of BAB III.pdf] Text
BAB III.pdf
Restricted to Registered users only

Download (573kB)
[thumbnail of BAB IV.pdf] Text
BAB IV.pdf
Restricted to Registered users only

Download (343kB)
[thumbnail of BAB V.pdf] Text
BAB V.pdf
Restricted to Registered users only

Download (84kB)
[thumbnail of Daftar Pustaka.pdf] Text
Daftar Pustaka.pdf

Download (87kB)

Abstract

Transformator pada sistem tenaga listrik adalah komponen utama yang sangat penting, sehingga transformator tersebut harus terlindungi dari adanyan gangguan-ganguan yang kemungkinan akan terjadi. Gangguan tersebut dapat dikurangi dan diatasi dengan menggunakan sistem proteksi. Salah satu proteksi yang digunakan pada transformator adalah Rele differensial, Rele Differensial merupakan pengaman utama terhadap gangguan arus lebih, ketidak seimbangan arus masuk ke rele dan gangguan hubung singkat transformator yang bekerja menggunakan prinsip seselektif dan secepat mungkin sistem kerjanya untuk mengatasi gangguan yang terjadi di dalam transformator. Dalam penulisan penyetelan rele differensial menggunakan metode observasi dan literatur. Pada penyetelan ini menggunakan beberapa tahap perhitungan untuk mendapatkan setelan dari rele differensial, diantaranya : Pemilihan perbandingan ratio CT utama yang dimana hasil yang diperoleh adalah 115,47 DI 150 kV dan 866,03 disisi 20 kV dengan rasio 150 : 1 disisi 150 kV dan 1000 : 1 disis 20 kV dengan menggunakan arus set differensial 0,3 A.

The transformers in the electrical power system use the many components that must be a very important, until the transformers must protected from the beginning disruption disorder likely to happen. The distraction can be reduce and be surmounted using the protection system on of the protection the transformers use is the differensial relay. The deferential relay is the safety of the more turbulence, an imbalanced influs of relay and a short circuity, the working system using the most selective and fast a system of work to cope with the disruption in the transformer. In a differential the relay differential using observation and literarure.On the adjustment ratio using a few stage of calculation to get the suit from the differentiated relay in particular : the selection of the ultimate ratio of CT to which the results are CT 115,47 on 150 kV and 866,03 on 20 kV with ratio 150 :1 disis 150 kV and 1000 : 1 disis 20 kV by using a differential settings of 0,3 A

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Transformer, Differential Rele, Protection Transformator, Rele Differensial, Proteksi
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 19 Feb 2026 06:49
Last Modified: 19 Feb 2026 06:49
URI: https://repository.itpln.ac.id/id/eprint/5127

Actions (login required)

View Item
View Item