SIDIQ, MUHAMMAD and Pasra, Nurmiati and Fernandes, Alex (2018) PENINGKATAN EFISIENSI MOTOR DRAINAGE PUMP PADA SAAT STARTING DENGAN MENGGUNAKAN PENGASUTAN STAR DELTA. Diploma thesis, ITPLN.
0. COVER.pdf
Download (164kB)
1. Lembar Pengesahan.pdf
Download (214kB)
6. ABSTRAK .pdf
Download (290kB)
12. BAB 1.pdf
Download (162kB)
13. BAB II.pdf
Download (1MB)
14. BAB III.pdf
Restricted to Registered users only
Download (368kB)
15. BAB IV.pdf
Restricted to Registered users only
Download (573kB)
16. BAB V.pdf
Restricted to Registered users only
Download (148kB)
17. DAFTAR PUSTAKA.pdf
Download (150kB)
Abstract
Pada motor 3 phasa yang semulanya diam apabila tegangan normalnya diberikan ke stator maka akan membutuhkan arus yang besar pada belitan primernya. Motor induksi 3 phasa saat dihidupkan secara langsung akan membutuhkan arus sebesar 8 kali arus nominal dan mampu menghasilkan torsi sebesar 2,5 kali dari torsi nominal pada saat starting motor menggunakan pengasutan Direct On Line. Besarnya arus dan torsi awal yang diperlukan pada pengasutan Direct On Line ini dapat menyebabkan winding pada motor menjadi panas sehinga menjadikan motor akan mengalami penurunan efisiensi, baik efisinsi daya motor yang digunakan pada saat start maupun berkurangnya life time motor akibat dari seringnya motor ini dioperasikan dalam keadaan arus yang tinggi. Oleh karena itu diperlukannya jenis pengasutan yang mampu mereduce arus starting salah satunya yaitu pengasutan Start Delta. Dengan penggunaan pengasutan Start Delta ini memiliki arus start yang lebih kecil dibandingkan dengan pengasutan sebelumnya yaitu 1,5 kali dari arus nominal.
In a 3 phase motor that is initially silent when a normal voltage is applied to the stator it will require a large current on the primary winding. 3 phase induction motors when powered on directly will require a current of 8 times the nominal current and capable of generating a torque of 2.5 times that of the nominal torque at the starting motor using Direct On Line starting. The amount of current and initial torque required on Direct On Line starting this can cause winding on the motor to heat so that the motor will experience a decrease in efficiency, both the motor power efficiency used at the start and reduced motor life time due to frequent motor is operated in a state high currents. Therefore, it is necessary to initiate the starting type which is capable of muffle the starting current, one of which is Start Delta starting. With the use of Start Delta starting it has a smaller start current compared to the previous start of 1.5 times the nominal current.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | 3 phase induction motor, current, Start Delta motor induksi 3 phasa, arus, Start Delta |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 19 Feb 2026 07:52 |
| Last Modified: | 19 Feb 2026 07:52 |