PEMASANGAN TRANSFORMATOR SISIP UNTUK MENGATASI BEBAN OVERLOAD PADA TRANSFORMATOR DISTRIBUSI DI PT. PLN (PERSERO) RAYON CILEGON

ARIANTO, ARDYAN SYS and Diantari, Retno Aita (2018) PEMASANGAN TRANSFORMATOR SISIP UNTUK MENGATASI BEBAN OVERLOAD PADA TRANSFORMATOR DISTRIBUSI DI PT. PLN (PERSERO) RAYON CILEGON. Diploma thesis, ITPLN.

[thumbnail of Cover.pdf] Text
Cover.pdf

Download (181kB)
[thumbnail of Lembar Lembar Pengesahan.pdf] Text
Lembar Lembar Pengesahan.pdf

Download (9MB)
[thumbnail of Abstrak.pdf] Text
Abstrak.pdf

Download (111kB)
[thumbnail of Abstract.pdf] Text
Abstract.pdf

Download (86kB)
[thumbnail of BAB I Pendahuluan.pdf] Text
BAB I Pendahuluan.pdf

Download (95kB)
[thumbnail of BAB II Landasan Teori.pdf] Text
BAB II Landasan Teori.pdf

Download (820kB)
[thumbnail of Bab III Metode Penelitian.pdf] Text
Bab III Metode Penelitian.pdf
Restricted to Registered users only

Download (438kB)
[thumbnail of Bab IV Hasil dan Pembahasan.pdf] Text
Bab IV Hasil dan Pembahasan.pdf
Restricted to Registered users only

Download (747kB)
[thumbnail of Bab V penutup.pdf] Text
Bab V penutup.pdf
Restricted to Registered users only

Download (85kB)
[thumbnail of Daftar Pustaka.pdf] Text
Daftar Pustaka.pdf

Download (99kB)

Abstract

Transformator Distribusi adalah merupakan suatu komponen yang sangat penting dalam penyaluran tenaga listrik dari gardu distribusi ke konsumen. Kerusakan pada transformator distribusi menyebabkan kontiniutas pelayanan terhadap konsumen akan terganggu (terjadi pemutusan aliran listrik atau pemadaman). Pemadaman merupakan suatu kerugian yang menyebabkan biaya-biaya pembangkitan akan meningkat tergantung harga KWH yang tidak terjual. Pemilihan rating transformator distribusi yang tidak sesuai dengan kebutuhan beban akan menyebabkan efisiensi menjadi kecil, begitu juga pembebanan pada transformator distribusi yang persentasenya melebihi 80% yang dapat mempengaruhi umur / life time suatu transformator distribusi dan mengurangi tingkat mutu pelayanan pada konsumen . Untuk itu diperlukan suatu tindakan agar transformator distribusi persentase pembebanannya tidak overload dengan cara menambah transformator sisip . Pada pembebanan transformator di Gardu Distribusi KPA persentase pembebanannya setelah dilakukan penambahan transformator di Gardu Sisip ALC menjadi 49,63% dan pembebanan transformator di Gardu Distribusi UKS persentase pembebanannya setelah dilakukan penambahan transformator di Gardu Sisip SUKS menjadi 49,51%.Dalam hal ini membuktikan bahwa persentase pembebananya menjadi rendah yang mulanya persentase pembebanannya lebih dari 80% ,sehingga dapat memperpanjang umur / life time transformator distribusi dan meningkatkan mutu pelayanan terhadap pelanggan.

Distribution transformer is a very important component in distributing electricity from the distribution substation to consumers. Damage to the distribution transformer causes the service continiutas to the consumer will be disrupted (the occurrence of electricity outages or blackouts). Extinction is a disadvantage that causes generating costs to increase depending on the price of unsold KWH. The selection of distribution transformer rating which is not suitable to the load requirement will cause the efficiency to be small, as well as the loading on the distribution transformer whose percentage exceeds 80% which can affect the life / life time of a distribution transformer and reduce the level of service quality to the consumer. Therefore, an action is needed so that the distribution transformer of the percentage of loading is not overloaded by adding the inner transformer. In the KPA Distribution Substation the percentage of loading after the addition of transformer in the Insert ALC to be 49.63% and the loading of the transformer in the Distribution Center of the UKS Distribution percentage of loading after the addition of transformer in SUS Inserted SUD to 49.51%. In this case proves that the percentage of the load becomes low which initially the percentage of loading is more than 80%, so it can extend the life / life time of the distribution transformer and improve the quality of service to the customer.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Transformator distribusi, efisiensi, beban overload transformator sisip Distribution transfrormer, efficiency, overload, insert transformer
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Vokasi > D3 Teknologi Listrik