PERBEDAAN CARA PEMASANGAN LIGHTNING ARRESTER TIPE LAMA DENGAN LIGHTNING ARRESTER TIPE BARU (SAi20z)

MULAIT, LABIA NATALIS and Pahiyanti, Novi Gusti (2017) PERBEDAAN CARA PEMASANGAN LIGHTNING ARRESTER TIPE LAMA DENGAN LIGHTNING ARRESTER TIPE BARU (SAi20z). Diploma thesis, ITPLN.

[thumbnail of 01 COVER.pdf] Text
01 COVER.pdf

Download (64kB)
[thumbnail of 1. Lembar pengesahan-1 natalis.pdf] Text
1. Lembar pengesahan-1 natalis.pdf

Download (116kB)
[thumbnail of 6. abstrak indonesia.pdf] Text
6. abstrak indonesia.pdf

Download (333kB)
[thumbnail of 7. abstrak bhs inggris.pdf] Text
7. abstrak bhs inggris.pdf

Download (31kB)
[thumbnail of BAB I.pdf] Text
BAB I.pdf

Download (51kB)
[thumbnail of BAB II.pdf] Text
BAB II.pdf

Download (414kB)
[thumbnail of BAB III.pdf] Text
BAB III.pdf
Restricted to Registered users only

Download (224kB)
[thumbnail of BAB IV.pdf] Text
BAB IV.pdf
Restricted to Registered users only

Download (626kB)
[thumbnail of BAB V.pdf] Text
BAB V.pdf
Restricted to Registered users only

Download (33kB)
[thumbnail of 17. Daftar Pustaka.pdf] Text
17. Daftar Pustaka.pdf

Download (89kB)

Abstract

PT.PLN (Persero) PUSLITBANG Ketenagalistrikan khususnya di Laboratorium Hubung Singkat Duri Kosambi, dimana alat – alat kelistrikan diuji untuk melihat atau mencocokkan apakah sudah sesuai dengan ( Standar PLN ) sebelum dipakai di PLN unit, salah satu alat kelitrikan yang diuji yaitu Lightning Arrester tipe baru (SAi20z), Arrester adalah sebagai alat pengaman Jika terjadi gangguan Arrester akan berfungsi sebagai konduktor dan jika saat normal arrester berfungsi sebagai isolator. Untuk arrester tipe lama menyalurkan tegangan lebih ke bumi sedangkan arrester tipe baru menyalurkan tegangan lebih melalui saluran keudara, dan arrester tipe lama kutup pentanahan terhubung dengan konduktor sedangkan arrester tipe baru memiliki (air gap) selah udara 6 cm kemudian jarak maksimal 8 cm antara konduktor dengan arrester Maka dari itu penulisan akan membahas tentang “Pemasangan Lightning Arester tipe lama dengan Lightning Arester tipe baru (Sai20z) pada jaringan (SUTM) 20 kV”

PT.PLN (Persero) PUSLITBANG Electricity, especially in Duri Kosambi Quick Connection Laboratory, where electrical appliances are tested to see or match whether it is in accordance with (PLN Standard) before it is used in PLN unit, one of the tested tools is Lightning Arrester type New (SAi20z), Arrester is as a safety device In case of interference Arrester will function as conductor and if normal time arrester function as isolator. For long-type arresters deliver more voltage to the earth while new type arresters supply more voltage through the air channel, and the old type of earth clamp arresters are connected to the conductor while the new type arrester has a 6 cm air gap and then a maximum distance of 8 cm between the conductor and Arrester. Therefore, the writing will discuss about "Installation of Lightning Arester of the old type with new type Lightning Arester (Sai20z) on network (SUTM) 20 kV".

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Old Arrester Lightning Arrester, New Array Lightning (SAi20z), Reliability of Protection System. Lightning Arrester Tipe Lama, Lightning Arrester Baru (SAi20z), Keandalan Sistem Proteksi.
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Vokasi > D3 Teknologi Listrik