PROSES PERAKITAN DAN PENGUJIAN KUBIKEL SM6 VACUUM CIRCUIT BREAKER 20 kV DI PT. GALLEON CAHAYA INVESTAMA

MUNAJICH, ACHMAD WIRO and Mangapul, Juara (2017) PROSES PERAKITAN DAN PENGUJIAN KUBIKEL SM6 VACUUM CIRCUIT BREAKER 20 kV DI PT. GALLEON CAHAYA INVESTAMA. Diploma thesis, ITPLN.

[thumbnail of 1. COVER.pdf] Text
1. COVER.pdf

Download (63kB)
[thumbnail of 2. lembar pengesahan.pdf] Text
2. lembar pengesahan.pdf

Download (68kB)
[thumbnail of 7. Abstrak.pdf] Text
7. Abstrak.pdf

Download (116kB)
[thumbnail of 11. BAB I.pdf] Text
11. BAB I.pdf

Download (43kB)
[thumbnail of 12. BAB II.pdf] Text
12. BAB II.pdf

Download (433kB)
[thumbnail of 13. BAB III.pdf] Text
13. BAB III.pdf
Restricted to Registered users only

Download (179kB)
[thumbnail of 14. BAB IV.pdf] Text
14. BAB IV.pdf
Restricted to Registered users only

Download (1MB)
[thumbnail of 15. BAB V.pdf] Text
15. BAB V.pdf
Restricted to Registered users only

Download (78kB)
[thumbnail of 16. Daftar Pustaka.pdf] Text
16. Daftar Pustaka.pdf

Download (9kB)

Abstract

Pada PT. Galleon Cahaya Investama dalam hal ini banyak yang dibutuhkan alat kelistrikan untuk di pergunakan pada jaringan distribusi yaitu salah satu alat kubikel sebelum dipasarkan pada perusahan lain kubikel adalah alat penghubung, pembagi dan memutuskan beban melakukan pengujian Pada pengujian isolasi kubikel ini kubikel sudah di pasang dan sudah tersambung dengan trafo setelah itu baru dilakukan pengujian isolasi dengan mega ohm meter, karna kubikel sudah tersambung dengan trafo maka nilai tahanan isolasi akan berkurang karna adanya trafo yang terdapat belitan di dalamnya. Pada pengujian kebocoran arus PMT komponennya masih dalam keadaan baik, dilihat dari hasil uji yaitu masih di bawah 300 μA, dan pada pengujian tahanan isolasinya, juga dalam keadaan baik, dilihat dari hasil yang telah di uji masih menunjukan nilai diatas standar tahanan isolasi. Dengan pemeriksaan visual dengan melihat hasil pekerjaan dengan mata maupun alat bantu, yaitu melihat bentuk, karatan dan penempatan komponen yang sudah tepat.

At PT. Galleon Cahaya Investama which in this case much needed electrical appliance to be used in distribution network that is one tool of cubicles before marketed at other company, cubicles is a connecting device, divider and disconnecting load doing testing. In this cubicle insulation testing, cubicle is already in pairs and have connected with The transformer after that just done insulation testing with mega ohm meter, because cubicle is already 5 with the transformer then the insulation resistance value will be reduced because of the existing transformer windings in it. In testing leakage current PMT component is still in good condition, seen from test results that is still Below 300 μA, and in the test of isolation resistance, also in good condition, Looking from the results that have been tested still shows the value above the standard isolation resistance. With visual inspection by looking at the results of work with the eyes and tools, namely see the shape, rust and placement of components that have been right.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Cubicle Vacum Circuit Breaker Protection 20 kV Kubikel Vacum Circuit Breaker Protection 20 kV
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 24 Feb 2026 06:40
Last Modified: 24 Feb 2026 06:40
URI: https://repository.itpln.ac.id/id/eprint/5237

Actions (login required)

View Item
View Item