PEMELIHARAAN INSTALASI KUBIKEL 2OKV PADA GARDU BETON DENGAN SISTEM CBM UNTUK PELANGGAN UMUM

SADDAD, FARAH DIBA and Mahari, Sukandi (2016) PEMELIHARAAN INSTALASI KUBIKEL 2OKV PADA GARDU BETON DENGAN SISTEM CBM UNTUK PELANGGAN UMUM. Diploma thesis, ITPLN.

[thumbnail of cover.pdf] Text
cover.pdf

Download (278kB)
[thumbnail of BAGIAN AWAL-1.pdf] Text
BAGIAN AWAL-1.pdf

Download (367kB)
[thumbnail of abstrak.pdf] Text
abstrak.pdf

Download (529kB)
[thumbnail of abstract.pdf] Text
abstract.pdf

Download (234kB)
[thumbnail of BAB I.pdf] Text
BAB I.pdf

Download (250kB)
[thumbnail of BAB II.pdf] Text
BAB II.pdf

Download (835kB)
[thumbnail of BAB III.pdf] Text
BAB III.pdf
Restricted to Registered users only

Download (459kB)
[thumbnail of BAB IV.pdf] Text
BAB IV.pdf
Restricted to Registered users only

Download (339kB)
[thumbnail of bab v.pdf] Text
bab v.pdf
Restricted to Registered users only

Download (246kB)

Abstract

Pada instalasi tenaga listrik dan peralatan elektrik banyak dijumpai panel panel yang digunakan untuk melindungi peralatan tersebut. Salah satunya adalah peralatan hubung bagi kendali untuk perancangan di dalam ruang pada tengangan menengah disebut “Metalclad Switchgear” atau umum disebut sebagai kubikel (Cubicle). Fungsinya adalah sebagai pengendali, penghubung dan pelindung serta membagi tenaga listrik dari sumber tenaga listrik. Dalam instalasi tegangan menengah kubikel diperlukan agar lebih mudah dalam pemantauan atau pemeliharaan sehingga peralatan listrik lebih awet. Seiring dengan berjalannya waktu, akibat pengaruh lingkungan dan efek operasi, kubikel mengalami penurunan kualitas pelayanan sehingga perlu dilakukan adanya upaya perawatan agar dapat mempertahankan atau mengembalikan pada tingkat prestasi awal dan dapat beroperasi dengan keandalan yang tinggi sehingga kontinuitas pelayanan listrik akan tercapai. Salah satu langkah pemeliharaan adalah yang bersifat prediktif yang umum disebut sebagai Conditional Base Maintenance. Adapun pemeliharaan ini dilakukan melalui pemeriksaan, deteksi, pencegahan kerusakan total yang tiba – tiba (breakdown). Dimana gangguan dapat terjadi akibat adanya faktor internal dan eksternal.

At the installation of electric power and electrical equipment found many panels that are used to protect the equipment. One of them is the equipment for the control circuit to the design in the space on the medium voltage called "Metalclad Switchgear" or commonly referred to as a cubicle (Cubicle). Its function is as a controller, connecting and protector and split the power from an electric power source. In the installation of medium voltage cubicles needed for easy monitoring of electrical equipment or maintenance so more durable. Over time, due to environmental influences and the effects of surgery, cubicles decreased quality of care that is necessary to their maintenance efforts in order to maintain or restore the initial achievement level and can operate with high reliability so that the continuity of the electrical service will be achieved. One step predictive maintenance is commonly referred to as Conditional Base Maintenance. The maintenance is done through inspection, detection, provention of sudden total damage (breakdown). Where interference can occur due to internal and external factors.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: kubikel, pemeliharaan, sistem CBM. cubicles, maintenance, CBM system.
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 13 Mar 2026 23:29
Last Modified: 13 Mar 2026 23:29
URI: https://repository.itpln.ac.id/id/eprint/6304

Actions (login required)

View Item
View Item