Pratama, Yorio Aspila and Sepriyanna, Irma (2018) ANALISIS DAYA DUKUNG, PENURUNAN SERTA PERHITUNGAN DIMENSI PILE CAP PONDASI TIANG BOR KELOMPOK (Studi kasus : Proyek Rusun Pasar Rumput Jakarta Selatan). Diploma thesis, ITPLN.
1. COVER.docx
Download (50kB)
2.LEMBAR PENGESAHAN.docx
Download (21kB)
3. LEMBAR PENGESAHAN TIM PENGUJI.docx
Download (22kB)
4. PERNYATAAN KEASLIAN SKRIPSI.docx
Download (20kB)
5.Kata Pengantar.docx
Download (19kB)
6. UCAPAN TERIMA KASIH.docx
Download (21kB)
7. HALAMAN PERSETUJUAN PUBLIKASI.docx
Download (23kB)
8 .ABSTRAK (INDONESIA).docx
Download (22kB)
8. ABSTRACT (INGGRIS).docx
Download (20kB)
9. DAFTAR ISI SKRIPSI.docx
Download (25kB)
10. Daftar Tabel.docx
Download (35kB)
11. DAFTAR GAMBAR SKRIPSI.docx
Download (16kB)
12. DAFTAR Notasi.docx
Download (21kB)
13. Daftar Lampiran.docx
Download (34kB)
BAB I.docx
Download (32kB)
BAB II.docx
Download (304kB)
BAB III.docx
Restricted to Registered users only
Download (48kB)
BAB IV.docx
Restricted to Registered users only
Download (101kB)
BAB V.docx
Restricted to Registered users only
Download (40kB)
DAFTAR PUSTAKA.docx
Download (21kB)
DAFTAR RIWAYAT HIDUP.docx
Download (56kB)
Abstract
Rusun Pasar Rumput memiliki 25 lantai, dengan lantai 1-3 berfungsi sebagai area pasar dan lantai 4-25 berfungsi sebagai area tempat tinggal. Sebagai bangunan yang tinggi, Rusun Pasar Rumput harus memiliki struktur yang kokoh dan juga kuat, bukan hanya struktur bagian atasnya saja, namun juga struktur bagian bawah. Namun dari hasil penyelidikan tanah yang dilakukan oleh PT. TITIK UTAMA AGUNG Geotechnical Engineering Consultant didapat jenis tanah adalah lempung kelanauan , jenis tanah ini agak sulit dilakukan untuk perencanaan pondasi karena bila tetap digunakan resiko penurunan yang terjadi akan sangat besar. Pondasi tiang bor kelompok dengan penambahan pile cap dapat membantu menopang beban bangunan, mereduksi penurunan serta membuat lokasi pembebanan yang bekerja benar benar berada di titik pusat pondasi sehingga tidak menyebabkan eksentrisitas yang dapat menyebabkan beban tambahan pada pondasi. Dengan menggunakan metode Reese dan O’niell (1989) dan metode Meyerhof (1976), kapasitas daya dukung tiang bor tunggal dengan diameter 1m dan kedalaman 20m adalah 153.80 ton dan 309.47 ton. kapasitas daya dukung tiang kelompok yang paling efisien serta bekerja mendekati maksimal berada pada pile cap no 4, besar efisiensi kelompok tiang berdasarkan metode Converse-Lebarre adalah 0.997 dengan kapasitas daya dukung tiang kelompok untuk tiga tiang yakni 460.01 ton dan 925.64 ton. Besar dimensi pile cap dengan panjang, lebar, tebal berdasarkan metode IS 456- 2000 adalah 3.3m , 3.3m , 2.9m. Penurunan pondasi tiang kelompok yang dianalisis dengan metode empiris dan semi-empiris untuk tiang tunggal dan penurunan tiang kelompok menggunakan metode vesic (1977) berturut-turut adalah 0.00561 m dan 0.01019 m, dinyatakan aman terhadap keruntuhan karena memenuhi syarat batas penurunan yang diizinkan yakni 0.1 m.
Pasar Rumput flats have 25 floors, with 1st – 3rd floors functioning as market areas and 4th – 25th floors functioning as residential areas. As a high building, Market grass flats must have a sturdy and strong structure, not just the upper structure, but also the lower structure. But from the results of the land investigation conducted by PT. TITIK UTAMA AGUNG Geotechnical Engineering Consultant obtained soil type is silty clay, this type of soil is rather difficult to do for planning the foundation because if it is still used the risk of settlement will be very large. The foundation of the group bored pile with the addition of pile cap can help support the building load, reduce the settlement and make the loading location that works properly at the center point of the foundation so as not to cause eccentricity which can cause additional loads on the foundation.Using the Reese and O'niell (1989) method and the Meyerhof (1976) method, the capacity of a single drill pole carrying capacity with a diameter of 1m and a depth of 20m is 153.80 tons and 309.47 tons. The carrying capacity of the pile group is the most efficient and works close to the maximum is in pile cap number 4, the size of the pile group efficiency based on the Converse-Lebarre method is 0.997 with the pile carrying capacity of the group for three piles is 460.01 tons and 925.64 tons. The dimensions of the pile cap with length, width, thickness based on the IS 456-2000 method are 3.3m, 3.3m, 2.9m. The settlement of group pile foundation analyzed by empirical and semi-empirical methods for single pile and group pile settlement using vesic method (1977) were 0.00561 m and 0.01019 m respectively, declared safe against collapse due to fulfilling the permissible decrease limit requirement of 0.1 m .
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Pondasi Tiang Kelompok, Daya Dukung, Penurunan, Dimensi Pile cap. Group Pile Foundation, Carrying Capacity, Settlement, Pile cap Dimension |
| Subjects: | Bidang Keilmuan > Teknik Sipil Skripsi |
| Divisions: | Fakultas Teknologi Infrastruktur dan Kewilayahan > S1 Teknik SIpil |
| Depositing User: | Sudarman |
| Date Deposited: | 11 Sep 2025 03:24 |
| Last Modified: | 11 Sep 2025 03:24 |
| URI: | https://repository.itpln.ac.id/id/eprint/893 |